Multi-stranded single-flex

Insulated multi-stranded copper wire in single form. Cross-sectional area from 1.5mm to 6mm available in RED or BLACK.

Suitable for small to medium currents over short lengths.

Multi-strand ripcord

This is a special ripcord with easy to identify red and black stripes. Available in cross-sectional areas of 1.5mm, 2.5mm and 4.0mm.

This cable is ideal for the installation of power outlets in vehicles.

Multi-strand heavy-duty cable

For high currents or battery connections, this heavy-duty cable is available with double-insulation and cross-sectional areas of 16mm, 25mm and 35mm.

Ideal for split-charge systems and general battery connections.

Average voltage loss per metre at specific currents (expressed as volts per metre) *
Cross sectional area (sq mm)
Volt-loss @ 10A
Volt-loss @ 20A
Volt-loss @ 40A
4mm
0.10v/m
0.19v/m
0.38v/m
6mm
0.06v/m
0.13v/m
0.26v/m
10mm
0.04v/m
0.08v/m
0.15v/m
16mm
0.02v/m
0.05v/m
0.10v/m
25mm
0.02v/m
0.03v/m
0.06v/m
35mm
0.01v/m
0.02v/m
0.04v/m
Total cable length must include the negative return path.

*The values shown in this table are average losses for anealed copper cable. Different cable manufacturers and or cable technology may exhibit different losses to those shown.